Brief Specifications

Input Voltage90 - 264 VAC (127 - 370 VDC)
Input Frequency47 - 63 Hz
Inrush Current< 48 Amps; Measured at 264 VAC, 25°C Ambient, Cold start
No Load Power< 0.5 W
Output Voltage5 V to 48 V
Output Power40 W
Voltage Tolerance± 1 %
Line Regulation< 1% of Vout
Load Regulation± 1 %
Turn On Time< 1 sec @ 230 VAC & < 3 sec @ 115 VAC, Full load
Hold Up Time≥60ms at 230V AC & ≥15ms at 115V AC, Full load
Rise Time< 100 ms
Overload Protection> 110% of rated output current; Hiccup type; Autorecovery
Overvoltage ProtectionLatched type; Input AC power to be recycled to recover the power supply
Output Short Circuit ProtectionHiccup mode when output is shorted; Autorecovery type
Operating Temp- 25°C to + 70°C; De-rate linearly above 50°C from 100 % load at 50°C to 50 % load at 70°C,- 25°C to 0°C start-up is guaranteed with specification deviation
Storage Temp- 40°C to + 85°C
CoolingNatural convection cooled
Humidity5 to 95 % RH, Non condensing
Altitude2000 m
DimensionOverall : 3” x 2” x 1.16” (LxWxH) ; Height above PCB : 1”
Weight< 100 gms
MountingOpen Frame

Product Variants

Product CodeDescriptionCertification
OPS2x3-40-05-A-1-CUOpen Frame Power Supply with 3 x 2 x 1.16 Inches Form factor, 5V, 5A, 25 Watts with Convection CoolingUL in Process
OPS2x3-40-12-A-1-CUOpen Frame Power Supply with 3 x 2 x 1.16 Inches Form factor, 12V, 3.33A, 40 Watts with Convection CoolingUL in Process
OPS2x3-40-15-A-1-CUOpen Frame Power Supply with 3 x 2 x 1.16 Inches Form factor, 15V, 2.67A, 40 Watts with Convection CoolingUL in Process
OPS2x3-40-24-A-1-CUOpen Frame Power Supply with 3 x 2 x 1.16 Inches Form factor, 24V, 1.67A, 40 Watts with Convection CoolingUL in Process
OPS2x3-40-48-A-1-CUOpen Frame Power Supply with 3 x 2 x 1.16 Inches Form factor, 48V, 0.83A, 40 Watts with Convection CoolingUL in Process

Downloads



We use cookies to enhance your user experience. By continuing to browse, you hereby agree to the use of cookies. To know more; visit our Privacy Policy & Cookies Policy

X